THC Measurement with a Flame Ionization Detector (FID)

← All measurement methods

The working principle of total hydrocarbon (THC), methane and VOC measurement by FID, its applications and the analyzers offered by Tetra.

Parameters measured with this method: CH₄ (Methane), THC / VOC (Hydrocarbons), BTEX / Benzene

How does an FID work?

A flame ionization detector (FID) burns the organic compounds in a sample in a hydrogen flame. Molecules containing carbon-hydrogen bonds ionize in the flame and create a measurable ion current between two electrodes. The current is approximately proportional to the number of carbon atoms passing through the flame, so the result is generally given in ppmC, as a methane or propane equivalent.

The detector uses hydrogen as fuel and combustion air. With direct sample injection, the instrument measures total hydrocarbons (THC). When a gas chromatography column is placed before the detector, methane and non-methane hydrocarbons (NMHC) can be measured separately.

What FID measures and where it is used

An FID is sensitive to hydrocarbons and volatile organic compounds (VOC). Main areas of use:

  • Emission monitoring and total organic carbon/THC measurement in flue gas
  • Methane, NMHC and VOC monitoring in ambient air
  • Measurements at landfill sites, biogas plants and around refineries
  • Fugitive emission (LDAR) surveys with portable instruments

Where FID works well and where it struggles

An FID has a wide linear range and a fast response; response factors are close to one another for many hydrocarbons. It is almost insensitive to water vapor, CO₂ and inert gases, which makes measurement in humid samples easier.

Limitations: the detector requires a flammable fuel such as hydrogen, which calls for planning in terms of site safety and gas supply. Because the response factor varies by component, results should be interpreted as equivalents. Large changes in oxygen content can affect the response. Heavy hydrocarbons tend to condense, so heated sample lines and heated detectors are used in high-temperature applications. An FID can respond less to partially oxidized and halogenated compounds; for such target components, a photoionization (PID) detector may be preferred.

Choosing an instrument for FID

When selecting, the type of target components (total hydrocarbons, methane separation or toxic VOCs), measurement range and sample temperature are assessed. Gas supply for fuel hydrogen and combustion air should be planned in advance for safe installation in the plant.

Tetra and FID analyzers

In Türkiye, Tetra carries out the supply, commissioning, calibration and service of FID-based analyzers. The product range includes the Thermo Scientific 51i total hydrocarbon analyzer (with a high-temperature option), the 55i methane/non-methane hydrocarbon analyzer, the TVA2020 portable toxic vapor analyzer (FID and PID together) and Synspec Alpha series FID/PID VOC analyzers. Synspec GC955 gas chromatographs can also be configured with an FID detector according to the application.

Products using this method

Thermo Scientific · Discontinued Thermo Scientific 51i Total Hydrocarbon (THC) Analyzer Thermo Scientific 51i flame ionization (FID) total hydrocarbon analyzer; heated (HT) version. Discontinued; service and spare parts in Türkiye from Tetra. View → Thermo Scientific Thermo Scientific TVA2020 Toxic Vapor Analyzer Thermo Scientific TVA2020 portable toxic vapor analyzer: FID and PID detectors, intrinsically safe. Sold and serviced in Türkiye by Tetra. View → Synspec Synspec Alpha Series FID/PID Benzene, Methane and VOC Analyzers Synspec Alpha analyzers measure methane/NMHC by FID and benzene, butadiene and vinyl chloride by PID in ambient air; from Tetra in Türkiye. View → Synspec Synspec GC955 Ambient Air BTEX, VOC and Benzene Gas Chromatograph Synspec GC955 is a gas chromatograph that continuously measures benzene, BTEX, butadiene, vinyl chloride and methane/NMHC in ambient air; from Tetra in Türkiye. View → Thermo Scientific Thermo Scientific 55i Methane / Non-Methane Hydrocarbon Analyzer Thermo Scientific 55i methane and non-methane hydrocarbon (NMHC) analyzer, FID-based. Sold, installed and serviced in Türkiye by Tetra. View → Synspec Synspec GC955 118 Methane and TNMHC Gas Chromatograph GC955 118 is a gas chromatograph that separately measures methane and total non-methane hydrocarbons by FID; offered in Türkiye by Tetra. View → Synspec Synspec Delta 116 CEMS Methane and Hydrocarbon Analyzer Delta 116 CEMS is a chromatographic CEMS analyzer that measures methane and other hydrocarbons by FID in high-range stack measurements; offered in Türkiye by Tetra. View →