M&C GenTwo V2.4 Multi-Gas Analyzer

← M&C TechGroup
M&C GenTwo V2.4

Measured parameters: CO (Carbon Monoxide), CO₂ (Carbon Dioxide), O₂ (Oxygen, Gas)

Measurement method: Paramagnetic Oxygen, NDIR / GFC, Electrochemical Sensor

M&C GenTwo V2.4 is a multi-gas analyzer with a modular sensor design that measures O2, CO2, CO, CH4 and other gases; from Tetra in Türkiye.

Installation, calibration, spare parts and service in Türkiye come from Tetra; cabinet and panel integration can be done at our İzmir facility.

Technical information

Measurement principles
NDIR, paramagnetic, electrochemical, thermal conductivity (WLD)
Measurement ranges
4 ranges per measurement, two adjustable
Relay outputs
4 per measurement signal
Enclosure protection
Rack IP20, wall-mounted IP54
Sample gas flow
25–60 Nl/h

GenTwo V2.4 is a modular multi-gas analyzer that can measure several components from the same sample stream. It is used in combustion control, process optimization, inerting monitoring and environmental protection applications. Which sensors are fitted is determined by the gases to be measured.

Sensor options and hardware

  • NDIR photometer: for polyatomic gases; up to three gases can be measured from a single bench.
  • Paramagnetic oxygen sensor: uses the paramagnetic property of oxygen and has no wearing parts.
  • Can be combined with electrochemical and thermal conductivity (WLD) sensors.
  • Modular design with up to six sensors, 7-inch touchscreen, 0/4-20 mA outputs and Modbus communication over Ethernet.
  • Four measurement ranges per measurement, two freely adjustable; four relay outputs.
  • 19-inch rack (IP20) or wall-mounted (IP54) housing; gas path selectable in Viton, PTFE or stainless steel.

Choosing GenTwo V2.4

Sample flow is in the range of 25-60 Nl/h, and pressure compensation is applied in the range of 0.8-1.2 bar absolute. When selecting, how many gases will be measured on one bench, whether oxygen will be paramagnetic or electrochemical and whether the housing will be rack or wall type are determined together.

Tetra arranges the sensor combination according to your measurement task and can integrate the analyzer into a cabinet or panel in İzmir. On site, zero-span calibration, sensor replacement and gas path checks are carried out in place.

Spare parts and consumables

Write to us for spare parts and consumables; the Tetra service team supplies and replaces the right original parts for your instrument.

Ask about spare parts →