NEO Monitors LaserGas Q NO and NO2 Laser Analyzer

← Neo Monitors
NEO Monitors Laser Gas Q

Measured parameters: NOₓ (Nitrogen Oxides)

Measurement method: TDLAS Laser Absorption

LaserGas Q monitors NO and NO2 gases by in-situ laser measurement, for emission and process applications; from Tetra in Türkiye.

Installation, calibration, spare parts and service in Türkiye come from Tetra; cabinet and panel integration can be done at our İzmir facility.

Technical information

Measurement principle
Laser absorption (in-situ)
Measured gases
NO, NO2
Optical path length
Typically 0.5 – 6 m
Response time
1 – 2 s
Outputs
3× 4–20 mA, TCP/IP, Modbus, 3 relays
Protection class
IP66

LaserGas Q is a laser analyzer family from NEO Monitors for measuring nitrogen oxides (NO and NO2) directly in line. Measurement takes place within the gas, between a transmitter and receiver mounted on either side of the duct; no sample line or conditioning is required. The optical path is typically 0.5 – 6 m, and response time is 1 – 2 seconds.

Available configurations cover NO and NO2 measuring instruments. It can be used for NOx emission monitoring and DeNOx (SCR/SNCR) control at cement, energy and waste incineration plants. Flange/purge kits and power/TU cables are supplied separately.

LaserGas Q features

  • In-situ laser measurement of NO and NO2
  • Optical path typically 0.5 – 6 m
  • Response time 1 – 2 s
  • IP66, -20 to +55 °C operating temperature
  • 3 analog outputs, TCP/IP, Modbus, 3 relays
  • Class 1 eye-safe laser, CE marked, IECEx/ATEX zone approvals

Spare parts and consumables

Write to us for spare parts and consumables; the Tetra service team supplies and replaces the right original parts for your instrument.

Ask about spare parts →
CONTACT

Let's choose the right product together

Tell us about your application; we will recommend the right model and configuration for the measuring point, process conditions and regulations.